J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38569760

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Adulto , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Sistema de Registros , Desenho de Prótese , Estudos Retrospectivos
2.
Circ Cardiovasc Interv ; : e013889, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38606564

RESUMO

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.

3.
Catheter Cardiovasc Interv ; 102(6): 1078-1087, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37925624

RESUMO

BACKGROUND: The Harmony TPV25 transcatheter pulmonary valve (Medtronic Inc.) is constructed with a self-expanding stent frame comprising six zigged nitinol wires sewn together and covered with knitted polyester fabric, with flared inflow and outflow ends and a porcine pericardial valve sutured to the central portion of the device. It was approved for treatment of pulmonary regurgitation after prior right ventricular outflow tract repair in 2021. Early outcomes of this procedure have been excellent, but little is known about valve durability or ultimate mechanisms of dysfunction. METHODS: We collected data on patients who underwent reintervention for TPV25 dysfunction and described findings related to distortion of the stent frame and tissue accumulation. RESULTS: We describe six patients who underwent valve-in-valve implant for TPV25 obstruction (peak catheterization gradient peak 28-73 mmHg) 10-28 months after implant. In all cases, there was tissue accumulation within the inflow and valve-housing segments of the device and deformation of the self-expanding valve frame characterized by variable circumferential narrowing at the junction between the valve housing and the inflow and outflow portions of the device, with additional geometric changes in all segments. All six patients underwent valve-in-valve implant that results in a final peak gradient ≤10 mmHg and no regurgitation. DISCUSSION: The occurrence of short-term Harmony TPV25 dysfunction in multiple patients with a similar appearance of frame distortion and tissue accumulation within the inflow and valve housing portions of the device suggests that this may be an important failure mechanism for this valve. Potential causes of the observed findings are discussed. It is possible to treat this mechanism of TPV25 dysfunction with valve-in-valve implant using balloon expandable transcatheter valves.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Obstrução da Via de Saída Ventricular Direita , Obstrução do Fluxo Ventricular Externo , Humanos , Suínos , Animais , Próteses Valvulares Cardíacas/efeitos adversos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Stents/efeitos adversos , Desenho de Prótese
4.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36995404

RESUMO

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Lactente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Sistema de Registros , Fatores de Tempo , Estudos Retrospectivos
5.
JACC Cardiovasc Interv ; 15(9): 979-988, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35512922

RESUMO

OBJECTIVES: The aim of this study was to evaluate the accuracy of cardiac magnetic resonance (CMR) in predicting coronary artery (CA) compression during transcatheter pulmonary valve implantation (TPVi). BACKGROUND: TPVi is a widely available option to treat dysfunctional right ventricle (RV)-to-pulmonary artery (PA) conduits, but CA compression is an absolute contraindication. CMR can evaluate coronary anatomy, but its utility in predicting CA compression is not well established. METHODS: After Institutional Review Board approval was obtained, all patients at 9 centers with attempted TPVi in RV-PA conduits and recent CMR (≤12 months) were analyzed. A core laboratory reviewed all CMR studies for the shortest orthogonal distance from a CA to the conduit, the shortest distance from a CA to the most stenotic area of the conduit, and subjective assessment of CA compression risk. RESULTS: Among 231 patients, TPVi was successful in 198 (86%); in 24 (10%), balloon testing precluded implantation (documented CA compression or high risk). Distance to the RV-PA conduit ≤2.1 mm (area under the curve [AUC]: 0.70) and distance to most stenotic area ≤13.1 mm (AUC: 0.69) predicted CA compression. Subjective assessment had the highest AUC (0.78), with 96% negative predictive value. Both distances and qualitative assessment remained independently associated with CA compression when controlling for abnormal coronary anatomy or degree of conduit calcification. CONCLUSIONS: CMR can help predict the risk for CA compression during TPVi in RV-PA conduits but cannot completely exclude CA compression. CMR may assist in patient selection and counseling families prior to TPVi, although balloon testing remains essential.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Cateterismo Cardíaco/efeitos adversos , Vasos Coronários , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Espectroscopia de Ressonância Magnética , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
6.
CJC Pediatr Congenit Heart Dis ; 1(4): 193-197, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37969931

RESUMO

Previous studies have used cardiopulmonary exercise test (CPET) data to objectively assess physiological changes in patients undergoing percutaneous pulmonary valve implantation. A retrospective review was performed to assess pre- and post-CPET data among patients undergoing Alterra Adaptive Prestent and SAPIEN 3 transcatheter heart valve (Alterra) placement. Of the 7 patients eligible for the study, 5 (71%) were male. The mean age was 22 years (range: 12-49 years). CPET data showed significant (P = 0.03) improvement in ventilatory efficiency (VE/VCO2) while only 2 (29%) patients had an improvement of percent predicted peak oxygen consumption (VO2). These findings suggest favourable haemodynamic changes though further investigation is needed.


Des résultats aux épreuves d'effort cardiorespiratoire ont été utilisés lors d'études antérieures pour mesurer de manière objective les changements physiologiques chez les patients ayant subi l'implantation percutanée d'une valvule pulmonaire. Nous présentons une étude rétrospective des résultats à ces épreuves avant et après l'intervention dans des cas d'implantation transcathéther d'une prothèse Alterra Adaptive Prestent et d'une valve cardiaque SAPIEN 3 (Alterra). Parmi les sept patients admissibles à l'étude, cinq (71 %) étaient de sexe masculin. L'âge moyen des sujets était de 22 ans (plage de 12 à 49 ans). Les résultats obtenus à l'épreuve d'effort cardiorespiratoire ont démontré une amélioration significative (P = 0,03) de l'efficacité respiratoire (VE/VCO2), mais seulement deux patients (29 %) ont présenté une amélioration du pourcentage prévu de la consommation maximale d'oxygène (VO2). Bien que ces observations semblent indiquer des changements hémodynamiques favorables, d'autres études sont nécessaires pour élucider la question.

7.
J Am Heart Assoc ; 11(1): e022832, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34935425

RESUMO

Background Advancements in the field, including novel procedures and multiple interventions, require an updated approach to accurately assess patient risk. This study aims to modernize patient hemodynamic and procedural risk classification through the creation of risk assessment tools to be used in congenital cardiac catheterization. Methods and Results Data were collected for all cases performed at sites participating in the C3PO (Congenital Cardiac Catheterization Project on Outcomes) multicenter registry. Between January 2014 and December 2017, 23 119 cases were recorded in 13 participating institutions, of which 88% of patients were <18 years of age and 25% <1 year of age; a high-severity adverse event occurred in 1193 (5.2%). Case types were defined by procedure(s) performed and grouped on the basis of association with the outcome, high-severity adverse event. Thirty-four unique case types were determined and stratified into 6 risk categories. Six hemodynamic indicator variables were empirically assessed, and a novel hemodynamic vulnerability score was determined by the frequency of high-severity adverse events. In a multivariable model, case-type risk category (odds ratios for category: 0=0.46, 1=1.00, 2=1.40, 3=2.68, 4=3.64, and 5=5.25; all P≤0.005) and hemodynamic vulnerability score (odds ratio for score: 0=1.00, 1=1.27, 2=1.89, and ≥3=2.03; all P≤0.006) remained independent predictors of patient risk. Conclusions These case-type risk categories and the weighted hemodynamic vulnerability score both serve as independent predictors of patient risk for high-severity adverse events. This contemporary procedure-type risk metric and weighted hemodynamic vulnerability score will improve our understanding of patient and procedural outcomes.


Assuntos
Cardiopatias Congênitas , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/etiologia , Cardiopatias Congênitas/terapia , Hemodinâmica , Humanos , Lactente , Razão de Chances , Sistema de Registros , Medição de Risco , Fatores de Risco
8.
Pediatr Cardiol ; 43(3): 695-699, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34668991

RESUMO

Exercise testing among the pediatric congenital heart disease population continues to transform and expand the way patients are evaluated and managed. We describe a case where a stress echocardiogram was performed while successfully collecting data from a previously implanted CardioMEMS™ HF system which helped guide decision-making.


Assuntos
Cardiopatias Congênitas , Insuficiência Cardíaca , Criança , Tomada de Decisão Clínica , Teste de Esforço , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Artéria Pulmonar
9.
Pediatr Cardiol ; 43(3): 596-604, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34743224

RESUMO

The objective of this study was to evaluate the impact of the regular introduction of new technologies into interventional cardiac catheterization procedures, in this case new atrial septal defect (ASD) closure devices, while conducting a multi-center collaborative initiative to reduce radiation usage during all procedures. Data were collected prospectively by 8 C3PO institutions between January 1, 2014 and December 31, 2017 for ASD device closure procedures in the cardiac catheterization lab during a quality improvement (QI) initiative aimed at reducing patient radiation exposure. Radiation exposure was measured in dose area product per body weight (µGy*m2/kg). Use of proposed practice change strategies at the beginning and end of the QI intervention period was assessed. Radiation exposure was summarized by institution and by initial type of device used for closure. This study included 602 ASD device closures. Without changes in patient characteristics, total fluoroscopy duration, or number of digital acquisitions, median radiation exposure decreased from 37 DAP/kg to 14 DAP/kg from 2014 to 2017. While all individual centers decreased overall median DAP/kg, the use of novel devices for ASD closure correlated with a temporary period of worsening institutional radiation exposure and increased fluoroscopy time. The introduction of new ASD closure devices resulted in increased radiation exposure during a QI project designed to reduce radiation exposure. Therefore, outcome assessment must be contextualized in QI projects, hospital evaluation, and public reporting, to acknowledge the expected variation during innovation and introduction of novel therapies.


Assuntos
Comunicação Interatrial , Exposição à Radiação , Dispositivo para Oclusão Septal , Cateterismo Cardíaco/métodos , Fluoroscopia/métodos , Comunicação Interatrial/cirurgia , Humanos , Melhoria de Qualidade , Doses de Radiação , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Resultado do Tratamento
11.
Pediatr Cardiol ; 42(6): 1410-1415, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33914123

RESUMO

For patients with single ventricle physiology, being able to initially establish systemic blood flow and control pulmonary blood flow is critical to their long-term health. Recently, there have been descriptions in achieving this by a purely transcatheter approach with stenting of the ductus arteriosus and implanting pulmonary flow restrictors, a very appealing prospect. We review a case series of 6 patients who underwent a percutaneous modified stage 1 approach using modified Microvascular plugs (MVP) at our center between September 2019 and December 2019. The initial procedure was technically successful in all patients with single-stage ductal stenting and placement of bilateral modified MVP via femoral access. Four patients underwent repeat cardiac catheterization prior to subsequent surgery that demonstrated elevated Qp:Qs (> 2:1) in 3 of the 4 patients with an elevated mean distal PA pressure > 20 mmHg in all patients. In some patients, the device migrated into the distal right pulmonary artery. One patient after Glenn shunt was found to have significant LPA stenosis requiring stenting. While the percutaneous modified stage 1 approach is a promising approach, we offer a word of caution against widespread adoption of this technique with the currently available devices.


Assuntos
Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/cirurgia , Canal Arterial/cirurgia , Hemodinâmica/fisiologia , Artéria Pulmonar/cirurgia , Stents , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Circulação Pulmonar , Fatores de Tempo , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 98(2): E262-E274, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33780150

RESUMO

OBJECTIVE: We compared 5-year outcomes of transcatheter pulmonary valve (TPV) replacement with the Melody TPV in the post-approval study (PAS) and the investigational device exemption (IDE) trial. BACKGROUND: As a condition of approval of the Melody TPV after the IDE trial, the Food and Drug Administration required that a PAS be conducted to evaluate outcomes of TPV replacement in a "real-world" environment. The 5-year outcomes of the PAS have not been published, and the IDE and PAS trials have not been compared. METHODS: The cohorts comprised all patients catheterized and implanted at 5 IDE sites and 10 PAS sites. Differences in trial protocols were detailed. Time-related outcomes and valve-related adverse events were compared between the two trials with Kaplan-Meier curves and log-rank testing. RESULTS: 167 patients (median age, 19 years) were catheterized and 150 underwent TPV replacement in the IDE trial; 121 were catheterized (median age, 17 years) and 100 implanted in the PAS. Freedom from hemodynamic dysfunction (p = .61) or any reintervention (p = .74) over time did not differ between trials. Freedom from stent fracture (p = .003) and transcatheter reintervention (p = .010) were longer in PAS, whereas freedom from explant (p = .020) and TPV endocarditis (p = .007) were shorter. Clinically important adverse events (AEs) were reported in 14% of PAS and 7.2% of IDE patients (p = .056); the incidence of any particular event was low in both. CONCLUSIONS: Hemodynamic and time-related outcomes in the PAS and IDE trials were generally similar, confirming the effectiveness of the Melody TPV with real-world providers. There were few significant complications and limited power to identify important differences in AEs. The lack of major differences in outcomes between the two studies questions the usefulness of mandated costly post-approval studies as part of the regulatory process for Class III medical devices.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Adulto Jovem
13.
J Thorac Cardiovasc Surg ; 161(3): 1139-1148, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33454101

RESUMO

OBJECTIVE: For children with severe pulmonary hypertension, addition of Potts shunt to a comprehensive palliation strategy might improve the outcomes afforded by medications and delay lung transplantation. METHODS: A prospective analysis was conducted of all children undergoing Potts shunt (first performed in 2013) or bilateral lung transplant for pulmonary hypertension from 1995 to present. RESULTS: A total of 23 children underwent Potts shunt (20 surgical, 3 transcatheter), and 31 children underwent lung transplant. All children with Potts shunt had suprasystemic right ventricle pressures despite maximal medical treatment. In the majority of patients, the Potts shunt was performed through a left thoracotomy approach (90%, 18/20), by direct anastomosis (65%, 13/20), and without the use of extracorporeal support (65%, 13/20). Perioperative outcomes after Potts shunt were superior to lung transplant including mechanical ventilation time (1.3 vs 10.2 days, P = .019), median hospital length of stay (9.8 vs 34 days, P = .012), and overall complication rate (35% [7/20] vs 81% [25/31], P = .003). Risk factors for operative mortality after Potts shunt (20%, 4/20; compared with 6%, 2/31 for lung transplant, P = .195) included preoperative extracorporeal membrane oxygenation and significant right ventricle dysfunction. In midterm follow-up (median 1.8, maximum 6.1 years), patients with Potts shunt had durable equalization of right ventricle/left ventricle pressures and improved functional status. There was no significant survival difference in patients with Potts shunt and patients with lung transplant (P = .258). CONCLUSIONS: Potts shunt is an effective palliation for children with suprasystemic pulmonary hypertension that may become part of a strategy to maximize longevity and functional status for these challenging patients.


Assuntos
Procedimentos Endovasculares , Hipertensão Pulmonar/cirurgia , Transplante de Pulmão , Cuidados Paliativos , Procedimentos Cirúrgicos Vasculares , Fatores Etários , Anastomose Cirúrgica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Hemodinâmica , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/mortalidade , Hipertensão Pulmonar/fisiopatologia , Transplante de Pulmão/efeitos adversos , Transplante de Pulmão/mortalidade , Estudos Prospectivos , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Stents , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade , Função Ventricular Esquerda , Função Ventricular Direita
14.
J Am Coll Cardiol ; 76(24): 2847-2858, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33303074

RESUMO

BACKGROUND: There are limited published data focused on outcomes of transcatheter pulmonary valve replacement (TPVR) with either a Sapien XT or Sapien 3 (S3) valve. OBJECTIVES: This study sought to report short-term outcomes in a large cohort of patients who underwent TPVR with either a Sapien XT or S3 valve. METHODS: Data were entered retrospectively into a multicenter registry for patients who underwent attempted TPVR with a Sapien XT or S3 valve. Patient-related, procedural, and short-term outcomes data were characterized overall and according to type of right ventricular outflow tract (RVOT) anatomy. RESULTS: Twenty-three centers enrolled a total of 774 patients: 397 (51%) with a native/patched RVOT; 183 (24%) with a conduit; and 194 (25%) with a bioprosthetic valve. The S3 was used in 78% of patients, and the XT was used in 22%, with most patients receiving a 29-mm (39%) or 26-mm (34%) valve. The implant was technically successful in 754 (97.4%) patients. Serious adverse events were reported in 67 patients (10%), with no difference between RVOT anatomy groups. Fourteen patients underwent urgent surgery. Nine patients had a second valve implanted. Among patients with available data, tricuspid valve injury was documented in 11 (1.7%), and 9 others (1.3%) had new moderate or severe regurgitation 2 grades higher than pre-implantation, for 20 (3.0%) total patients with tricuspid valve complications. Valve function at discharge was excellent in most patients, but 58 (8.5%) had moderate or greater pulmonary regurgitation or maximum Doppler gradients >40 mm Hg. During limited follow-up (n = 349; median: 12 months), 9 patients were diagnosed with endocarditis, and 17 additional patients underwent surgical valve replacement or valve-in-valve TPVR. CONCLUSIONS: Acute outcomes after TPVR with balloon-expandable valves were generally excellent in all types of RVOT. Additional data and longer follow-up will be necessary to gain insight into these issues.


Assuntos
Procedimentos Endovasculares/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Próteses Valvulares Cardíacas , Valva Pulmonar , Sistema de Registros , Adolescente , Adulto , Bioprótese , Criança , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
15.
JACC Cardiovasc Interv ; 13(21): 2510-2524, 2020 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-33069657

RESUMO

OBJECTIVES: The aim of this study was to demonstrate the safety and functionality of the Alterra Adaptive Prestent and SAPIEN 3 transcatheter heart valve (THV) in patients with dysfunctional, dilated right ventricular outflow tract (RVOT) greater or equal to moderate pulmonary regurgitation (PR). BACKGROUND: Significant variations in the size and morphology of the RVOT affect the placement of transcatheter pulmonary valves. The Alterra Prestent internally reduces and reconfigures the RVOT, providing a stable landing zone for the 29-mm SAPIEN 3 THV. METHODS: Eligible patients had moderate or greater PR, weighed >20 kg, and had RVOT diameter 27 to 38 mm and length >35 mm. The primary endpoint was device success, a 5-item composite: 1 Alterra Prestent deployed in the desired location, 1 SAPIEN 3 THV implanted in the desired location within the Prestent, right ventricular-to-pulmonary artery peak-to-peak gradient <35 mm Hg after THV implantation, less than moderate PR at discharge, and no explantation 24 h post-implantation. The secondary composite endpoint was freedom from THV dysfunction (RVOT/pulmonary valve (PV) reintervention, greater or equal to moderate total PR, mean RVOT/PV gradient ≥ 35 mm Hg at 30 days and 6 months. Descriptive statistics are reported. RESULTS: Enrolled patients (N = 15) had a median age and weight of 20 years and 61.7 kg, respectively; 93.3% were in New York Heart Association functional class I or II. Device success was 100%. No staged procedures were necessary. No THV dysfunction was reported to 6 months. No serious safety signals were reported. CONCLUSIONS: This early feasibility study demonstrated the safety and functionality of the Alterra Adaptive Prestent in patients with congenital RVOT dysfunction and moderate or greater PR. Durability and long-term outcome data are needed.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Cateterismo Cardíaco , Estudos de Viabilidade , Humanos , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento
16.
JACC Cardiovasc Interv ; 13(13): 1529-1540, 2020 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-32646693

RESUMO

OBJECTIVES: The aim of this analysis was to evaluate outcomes following transcatheter reintervention for degenerated transcatheter pulmonary valves (TPVs). BACKGROUND: TPV replacement (TPVR) with the Melody valve demonstrated sustained relief of right ventricular outflow tract (RVOT) obstruction and pulmonary regurgitation. METHODS: All patients who underwent TPVR with a Melody valve as part of 3 Medtronic-sponsored prospective multicenter studies were included. Transcatheter reinterventions included balloon dilation of the previously implanted Melody valve, placement of a bare-metal stent within the implanted TPV, or placement of a new TPV in the RVOT (TPV-in-TPV). Indications for reintervention, decisions to reintervene, and the method of reintervention were at physician discretion. All patients provided written informed consent to participate in the trials, and each trial was approved by local or central Institutional Review Boards or ethics committees at participating sites. RESULTS: A total of 309 patients who underwent TPVR were discharged from the implantation hospitalization with Melody valves in place. Transcatheter reintervention on the TPV was performed in 46 patients. The first transcatheter reintervention consisted of TPV-in-TPV in 28 patients (median 6.9 years [quartile 1 to quartile 3: 5.2 to 7.8 years] after TPVR), simple balloon dilation of the implanted Melody valve in 17 (median 4.9 years [quartile 1 to quartile 3: 4.0 to 6.0 years] after TPVR), and bare-metal stent placement alone in 1 (4.4 years after TPVR). There were no major procedural complications. Overall, 4-year freedom from explant and from any later RVOT reintervention after the first reintervention were 83% and 60%, respectively. Freedom from repeat RVOT reintervention was longer in patients undergoing TPV-in-TPV than balloon dilation (71% vs. 46% at 4 years; p = 0.027). CONCLUSIONS: TPV-in-TPV can be an effective and durable treatment for Melody valve dysfunction. Although balloon dilation of the Melody valve was also acutely effective at reducing RVOT obstruction, the durability of this therapy was limited in this cohort compared with TPV-in-TPV.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Adulto , Valvuloplastia com Balão , Cateterismo Cardíaco/efeitos adversos , Criança , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Adulto Jovem
17.
Circ Cardiovasc Interv ; 13(5): e008172, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32408819

RESUMO

BACKGROUND: The C3PO-QI (Congenital Cardiac Catheterization Project on Outcomes - Quality Improvement), a multicenter registry launched in 2015, instituted quality improvement (QI) initiatives to reduce patient radiation exposure. Through regular collaboration, this initiative would allow for harmony among active participants, maximizing efforts and efficiency at achieving radiation best practices. This study sought to report these efforts with a detailed methodology for which institutions can target initiatives, reducing radiation exposure, and increasing patient safety. METHODS: Data were collected prospectively by 8 C3PO-QI institutions between January 1, 2015 and December 31, 2017. Radiation exposure was measured in dose area product per body weight (dose area product/kg; µGy*m2/kg) and reported by expected radiation exposure categories (REC) and institution for 40 published unique procedure types. Targeted interventions addressing selected strategic domains for radiation reduction were implemented in the pediatric catheterization labs of the C3PO-QI institutions. RESULTS: The study consisted of 15 257 unique cases. Median exposure (dose area product/kg) was decreased by 30% for all procedures. Dose area product/kg was reduced in all 3 REC, with the greatest improvement observed in REC I (REC I, -37%; REC II, -23%; REC III, -27%). Although the baseline radiation exposures and exact percent decrease varied across all C3PO-QI sites, each institution demonstrated improvements in radiation dose over time. These improvements occurred with the implementation of institution-specific QI interventions accelerated by participation in the C3PO-QI multicenter collaborative. CONCLUSIONS: Substantial radiation dose reductions can be achieved using targeted QI methodology and interventions. Participation in a multicenter QI collaborative may accelerate improvement across all centers due to enhanced engagement and shared learning between sites.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Doses de Radiação , Exposição à Radiação/prevenção & controle , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Angiografia Coronária/efeitos adversos , Bases de Dados Factuais , Feminino , Disparidades em Assistência à Saúde , Humanos , Lactente , Masculino , Segurança do Paciente , Estudos Prospectivos , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Exposição à Radiação/efeitos adversos , Lesões por Radiação/etiologia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Adulto Jovem
18.
J Am Soc Echocardiogr ; 33(2): 207-217, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31699474

RESUMO

BACKGROUND: Doppler pressure gradients (PGs) are routinely used as a surrogate for catheter peak-to-peak gradient (PPG) for referring pediatric patients with aortic stenosis (AS), pulmonary stenosis (PS), and coarctation of the aorta (CoA) for intervention but do not always predict the catheter PPG accurately, which results in misclassification of lesion severity. We hypothesized that recovered pressure (RP) accounts for the discrepancy between Doppler PG and catheter PPG. We aimed to study the occurrence of clinically significant RP in AS, PS, and CoA. METHODS: Simultaneous Doppler and catheter PGs were prospectively measured in 82 patients (median age, 12.2 months; weight, 7.5 kg) with isolated AS (n = 30), PS (n = 24), and CoA (n = 28), and agreement before and after correcting for RP were analyzed. RP was calculated from a fluid dynamic-based equation. Effects of lesion geometry on the magnitude of RP were analyzed. RESULTS: Recovered pressure-corrected Doppler peak instantaneous gradient (PIG) had significantly closer agreement and correlation with the catheter PPG (P < .001) than the uncorrected PIG and mean Doppler gradients. Recovered pressure-corrected Doppler PIG predicted PPG with high specificity and accuracy in all lesions (95% CI, 36%-97% and 85%-100%, respectively, P < .05 for both). RP magnitude was weakly related (r = 0.33 to 0.47) to valve area and inversely related (r = -0.22 to -0.34) to downstream vessel area. CONCLUSIONS: Significant RP occurs in congenital AS, PS, and CoA, accounting for misclassification of lesion severity by Doppler PIG. The RP magnitude is at a maximum in mild to moderate stenotic outflow lesions, with small-size downstream vessels causing the most misclassification of lesion severity by Doppler PIG.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Pressão Sanguínea/fisiologia , Cateteres Cardíacos , Ecocardiografia Doppler/métodos , Adolescente , Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/diagnóstico , Cateterismo Cardíaco , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Masculino , Estudos Prospectivos , Índice de Gravidade de Doença , Adulto Jovem
19.
Methodist Debakey Cardiovasc J ; 15(2): 122-132, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31384375

RESUMO

Right ventricular outflow tract (RVOT) dysfunction is common following surgical repair of tetralogy of Fallot and other forms of complex congenital heart disease. This results in pulmonary stenosis or regurgitation and may ultimately lead to RV failure and dysrhythmias. Transcatheter valve technologies are now available to treat certain patients with RVOT dysfunction. Current devices include the Medtronic Melody valve and the Edwards Lifesciences SAPIEN XT. Although these valves are approved for use in dysfunctional circumferential RVOT conduits, they are increasingly being used off label for nonconduit outflow tracts. Procedural complications include but are not limited to conduit rupture and coronary compression. Longer-term complications include stent fracture and endocarditis. Outcomes with these valves have demonstrated durable relief of stenosis and regurgitation. The Medtronic Harmony valve and the Alterra Prestent from Edwards Lifesciences are investigational devices that are intended to treat the patulous RVOT that is too large to accommodate currently available valves. This review will focus on current indications to treat RVOT dysfunction, existing transcatheter valve technologies, and investigational devices undergoing clinical trials. Hopefully, within the not-too-distant future, transcatheter pulmonary valve implantation will be feasible in the vast majority of patients with RVOT dysfunction following surgical repair of congenital heart disease.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/etiologia , Estenose da Valva Pulmonar/fisiopatologia , Fatores de Risco , Tetralogia de Fallot/fisiopatologia , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia
20.
J Surg Res ; 243: 41-46, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31154131

RESUMO

BACKGROUND: Studies comparing percutaneous closure of patent ductus arteriosus (PDA) with surgical ligation tend to exclude premature infants and have not assessed procedural charges. We compared our contemporary outcomes and charges of device closure to surgical ligation of PDA in preterm infants. MATERIAL AND METHODS: Preterm infants who underwent isolated PDA closure during their newborn hospitalization (January 2014 to September 2017) were grouped based on intention to treat (surgery versus device closure). Patient demographics, procedural details, and immediate postprocedural outcomes were compared. Procedural charges for device closure versus surgical ligation were compared. RESULTS: Compared with the device group (n = 33), patients undergoing surgical ligation (n = 39) were younger, smaller, and required more preoperative support (P < 0.05). The procedure time was shorter for surgical ligation (P < 0.01). Although there was no procedural mortality in either group, the complication rate was higher for device closure than for surgical ligation (15.2% versus 0%; P = 0.02). The proportion of patients returning to preprocedural respiratory support by 48 h after procedure was similar. There was a higher proportion of surgical patients who required increased inotropic support in the first 24 h after procedure (P = 0.19). The procedural charges for transcatheter device closure were twice as expensive as those for surgical ligation. CONCLUSIONS: In our early experience with percutaneous PDA closure, we found a percutaneous approach in preterm infants feasible and well tolerated. Both surgical ligation and device closure were associated with perioperative or postoperative complications. Procedural charges were higher for percutaneous closure, driven by device charge and catheterization room utilization. Further investigation is needed to establish guidelines for first-line therapy for PDA closure in preterm infants, including cost-benefit analysis.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Permeabilidade do Canal Arterial/terapia , Doenças do Prematuro/terapia , Cateterismo Cardíaco/instrumentação , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Análise de Intenção de Tratamento , Ligadura , Masculino , Estudos Retrospectivos , Resultado do Tratamento